115-23-2045 2/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TS MV-105 175mils 15KV Power Cable
Original price was: $10.00.$8.00Current price is: $8.00.
(In Stock)
[pdf] [/pdf]
115-23-2045 2/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TS MV-105 175mils 15KV Power Cable
Allowable Ampacity for 115-23-2045 2/0 AWG 1C Stranded Uncoated Copper Shield Okoguard Okoclear-TS MV-105 175mils 15KV Power Cable:100 Amps
About:
This specific model of power cable uses a 2/0 AWG stranded uncoated copper conductor, offering flexibility and substantial conductivity. It features Okoguard insulation, which is an ethylene-propylene rubber (EPR) compound known for its high dielectric strength and resistance to thermal aging and moisture ingress. The Okoclear-TS jacketing is a non-conductive thermosetting semi-conducting shield, enhancing the cables overall durability and electrical properties. The “MV-105” designation refers to its medium voltage capability, suitable for operations up to 15KV, with a conductor temperature rating of 105C. The insulation thickness for this model is 175 mils, providing enhanced electrical isolation and mechanical protection.
Also Known As:
2/0 AWG MV-105 15KV Power Cable
Okoguard 15KV Cable
High Voltage Stranded Copper Cable
Applications:
Okoguard shielded Okoclear-TS Type MV-105 power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations, where a cable with low smoke/zero halogen characteristics is needed.
Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed
to sunlight), in any raceway or underground duct, directly buried if installed in a system
with a grounding conductor in close proximity that conforms with NEC Section 315.36 and 250.4(A)(5), or messenger supported in industrial establishments and electric utilities.
May be installed in cable trays where permitted by NEC Section 392 as permitted by NEC Section 315.32(3).
Standards:
UL 1072 (Standard for Medium Voltage Power Cables) for safe use in electrical distribution and transmission
ICEA S-93-639/NEMA WC 74 (Standard for Shielded Power Cables for Use in the Transmission and Distribution of Electric Energy)
IEEE 1202 (Standard for Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies) for fire resistance
AEIC CS8 (Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV)
Construction:
Conductor:Uncoated copper compact stranded per ASTM B-496.
Strand Screen:Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.10 and UL 1072.
Insulation:Meets or exceeds electrical and physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.10 and UL 1072.
Insulation Screen:Extruded semiconduction EPR insulation screen. Meets or exceeds electrical and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEIC CS8, CSA C68.10 and UL 1072.
Shield:5 mil bare copper tape helically applied, with 25% minimum overlap.
Jacket:Meets or exceeds electrical and physical requirements of ICEA S-93-639 and CSA C68.10 for Type II crosslinked polyolefin jackets.
UL listed as Type MV-105, sunlight resistant and for use in cable tray in
accordance with UL 1072.
CSA C68.10 listed as FT4-ST1, HALOGEN-FREE, LTDD (-25C), and TC-ER
Features:
Low smoke/zero halogen jacket.
Okoguard cables meet or exceed all recognized industry standards (UL, NEMA/ICEA and IEEE).
Triple tandem extruded, all EPR system.
105C continuous operating temperature.
140C emergency rating.
250C short circuit rating
Excellent corona resistance.
Exceptional resistance to treeing.
Screens are clean stripping.
Exceptional resistance to moisture.
Resistant to most oils, acids, and alkalis.
UL listed: MV-105, Sunlight Resistant, Cable Tray Use, and Oil Res I & II.
Passes the UL & IEEE 383-1974 and FT4/IEEE 1202 Vertical Tray Flame Test.
Specifications:
Conductor Size AWG: 2/0
Conduit Size Inches (5):3
Approx. Dia. over Insulation (in.): 0.77
Jacket Thickness (mm):2.03
Approx. O.D. (Inches): 1.04
Approx. Net Weight: 935
Ampacities Conduit in Air (2 ): 255
Ampacities Underground Duct (3): 245
Ampacities Cable Tray (4): 335
Part Number: 115-23-2045