Allowable Ampacity for 2/0-2/0-1 ALUMINUM SER CABLE at 60C: 115 Amps
Allowable Ampacity for 2/0-2/0-1 ALUMINUM SER CABLE at 75C: 135 Amps
Allowable Ampacity for 2/0-2/0-1 ALUMINUM SER CABLE at 90C: 150 Amps
Applications:
Aluminum service entrance cable is mainly used in branch circuits and panel feeders. The voltage rating for this electrical cable is 600 volts. Aluminumservice entrance cables are designed for use in adverse weather conditions, with operating temperatures being 90C in both wet and dry locations.
However, type R cables can operate at 60C when terminated to equipment for circuits rated at 100 Amps or less or if it is marked for 14 gauge through 1 gauge conductors. In addition, SER cables can operate at 70C when the electrical cable is terminated to equipment in circuits rated over 100 Amps or when marked for conductors larger than 1 gauge.
Also Known As:
2/0-2/0-1 type r cable,2/0-2/0-1service entrance cable, 2/0-2/0-1 ser cable, 2/0-2/0-1 aluminum ser cable, 2/0-2/0-1 aluminum service entrance cable, 2/0-2/0-1electrical entrance cable.
Standards:
-
Ampacities based on National Electric Code, 2005 edition, section 310-15
-
60C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors
-
70C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge
-
90C wet or dry locations
-
For dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single phase service conductors that supply the total load
-
UL 44
Construction
Conductors:
Aluminum type R cable has compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801. The conductor is the electrode in the cable and is responsible for transmitting electric current.
Insulation:
Aluminum SER cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum ground and covered with a reinforced binder tape. For color code, see table B in the technical section.
Jacket:
The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.
Specifications:
-
Insulated Cond(s) Size AWG: 2/0
-
Bare Conductor Size AWG: 1
-
Nominal O.D. Inches: 0.951
-
Approx. Weight lb/1000FT: 459 lbs
-
Ampacity at 90C: 150 Amps
-
Ampacity in dwelling: 150 Amps
Compatible with Manufacturer |
|
Houston Wire & Cable : | HW022A20201 |
Reviews