500′ 1/0-1/0-2 ALUMINUM SEU CABLE
Original price was: $1,800.00.$98.00Current price is: $98.00.
(In Stock)
[pdf] [/pdf]
[short]
1/0-1/0-2 ALUMINUM SEU CABLE
Allowable Ampacity for 1/0-1/0-2 ALUMINUM SEU CABLE at 60C: 100 Amps
Allowable Ampacity for 1/0-1/0-2 ALUMINUM SEU CABLE at 75C: 120 Amps
Allowable Ampacity for 1/0-1/0-2 ALUMINUM SEU CABLE at 90C: 135 Amps
Applications:
Aluminum SEU cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature of this electrical cable is not to exceed 90C in wet locations. Voltage rating for this electrical cable is 600 volts.
Also Known As:
1/0-1/0-2aluminum seu cable, 1/0-1/0-2seu service entrance cable, 1/0-1/0-2seu cable, 1/0-1/0-2seu wire,1/0-1/0-2600v wire,1/0-1/0-2600v cable, aluminum cable
Standards:
-
Ampacities based on National Electric Code, 2005 edition, section 310-15
-
60C when terminated to equipment for circuits rated 100 Amps or less or marked for 14 gauge through 1 gauge conductors
-
70C when terminated to equipment for circuits rated over 100 Amps or marked for conductors larger than 1 gauge
-
90C wet or dry locations
-
For dwelling units, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service conductors that supply the total load
-
UL 44, 854
-
Federal Specification J-C – 30B
Construction
Conductors:
Aluminum SEU cable has compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801. The conductor is the electrode in the cable and is responsible for transmitting electric current.
Insulation:
Aluminum SEU cable has a type XHHW-2 cross-linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum ground and covered with a reinforced binder tape. For color code, see table B in the technical section.
Jacket:
The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket.
Specifications:
-
Insulated Cond(s) Size AWG: 1/0
-
Bare Conductor Size AWG: 2
-
Nominal O.D. Inches: 0.647
-
Approx. Weight lb/1000FT: 574 lbs
-
Ampacity at 90C: 135 Amps
-
Ampacity in dwelling: 125 Amps
Compatible with Manufacturer |
|
Priority Wire & Cable : | 1/0-02ALUMG-R-SEU |
[/short]
Application:
Aluminum SEU cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits. Maximum operating temperature is not to exceed 90C in wet locations. Voltage rating is 600 volts.
Conductors:
Aluminum SEU cable has a compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801
Insulation:
Aluminum SEU cable has a type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with a bare copper ground and covered with a reinforced binder tape.
Jacket:
Aluminum SEU cable has a gray sunlight resistance polyvinyl chloride (PVC) jacket.
Standards:
- Ampacities based on National Electric Code, 2005 edition, section 310-15
- 60C when terminated to equipment for circuits rated 100amps or less or marked for 14ga through 1ga conductors
- 70C when terminated to equipment for circuits rated over 100amps or marked for conductors larger than 1ga
- 90C wet or dry locations
- For dwelling units, conductors shall be permitted at listed Ampacities to be utilized as 120/240 volt, 3-wire, single phase service
- conductors that supply the total load
- UL 44, 854
- Federal Specification J-C – 30B
Reviews
There are no reviews yet.